NMR Spectroscopy
- Varian Unity-Inova 400 MHz NMR Spectrometer
- 2 RF channels
- z-axis pulsed field gradient equipped (hardware and probe)
- Varian quad-nucleus probe, capable of 1H and 19F detection (high band) and 13C and 31P detection (low band), plus X (low band) tunable between 15N and 31P (e.g., 7Li, 15N, 17O, 23Na, 29Si, 77Se, 119Sn)
- Varian Unity-Inova 500 MHz NMR Spectrometer
- Waveform generators
- z-axis pulsed field gradient equipped (hardware and all probes)
- Varian triple-resonance, inverse-detection probe, capable of 1H{13C/X} experiments, with X tunable between 15N and 31P
- Protasis/MRM inverse-detection, capillary probe, capable of 1H{13C} experiments, with a 5 µL sample volume (for mass-limited samples)
- Nalorac quad-nucleus probe, capable of 1H and 19F detection (high band) and 13C and 31P detection (low band)
Mass Spectrometry
- IonSpec ProMALDI FT Mass Spectrometer
- Matrix assisted laser desorption ionization (MALDI) source with hexapole ion accumulation and cooling
- 7 Tesla, actively shielded, superconducting magnet
- 192-sample target plates
- Agilent 1100 HPLC-MSD SL Quadrupole Mass Spectrometer
- Binary pump HPLC with microvacuum degaser
- Temperature controlled, 100-vial autosampler
- Dual column oven with a column switching valve
o UV/Vis diode array detector
o Orthogonal pneumatically assisted electrospray (ESI) and atmospheric pressure chemical ionization (APCI) sources
- Agilent 1100 HPLC-MSD SL Ion Trap Mass Spectrometer
- Binary pump HPLC with microvacuum degaser
- Temperature controlled, 100-vial autosampler
- Dual column oven with a column switching valve
- UV/Vis diode array detector
- Orthogonal pneumatically assisted electrospray (ESI) and atmospheric pressure chemical ionization (APCI) sources
- Agilent 1100 HPLC-MSD VL Quadrupole Mass Spectrometer
- Quaternary pump HPLC
- 100-vial autosampler
- UV/Vis variable wavelength detector
- Atmospheric pressure chemical ionization (APCI) source
Spectrophotometry
- Bruker Equinox 55/S FT–IR Spectrophotometer
- Conventional and step scanning modes for time-resolved spectroscopy
- Fast scan option
- Dual sources for Near-IR and Mid-IR spectral ranges
- DTGS, liquid-nitrogen-cooled MCT, and NIR Ge diode detectors
- Various sampling accessories are available
- Perkin–Elmer 599B IR Spectrophotometer
- Double beam, optical null instrument with an f/5 filter grating monochrocator
- 4000 to 200 cm–1 spectral range
- Transmission cell holder
- Hitachi F–3010 Fluorescence Spectrophotometer
- Excitation or emission wavelength scans, time scan and quantitative measurement modes
- Temperature-controlled cuvette holder with integrated stirring accessory
- Perkin–Elmer 241 Polarimeter
- Sodium and mercury lamp sources
- Temperature-controlled cell having 1 mL volume and 1 dm pathlength
Miscellanea
- Nikon Inverted Microscope