Analytical Instrumentation Center - Instrumentation

Navigation Options

Instrumentation


NMR Spectroscopy

  • Varian Unity-Inova 400 MHz NMR Spectrometer
    • 2 RF channels
    • z-axis pulsed field gradient equipped (hardware and probe)
    • Varian quad-nucleus probe, capable of 1H and 19F detection (high band) and 13C and 31P detection (low band), plus X (low band) tunable between 15N and 31P (e.g., 7Li, 15N, 17O, 23Na, 29Si, 77Se, 119Sn)
  • Varian Unity-Inova 500 MHz NMR Spectrometer
    • 3 RF channels
    • Waveform generators
    • z-axis pulsed field gradient equipped (hardware and all probes)
    • Varian triple-resonance, inverse-detection probe, capable of 1H{13C/X} experiments, with X tunable between 15N and 31P
    • Protasis/MRM inverse-detection, capillary probe, capable of 1H{13C} experiments, with a 5 µL sample volume (for mass-limited samples)
    • Nalorac quad-nucleus probe, capable of 1H and 19F detection (high band) and 13C and 31P detection (low band)

Mass Spectrometry

  • IonSpec ProMALDI FT Mass Spectrometer
    • Matrix assisted laser desorption ionization (MALDI) source with hexapole ion accumulation and cooling
    • 7 Tesla, actively shielded, superconducting magnet
    • 192-sample target plates
  • Agilent 1100 HPLC-MSD SL Quadrupole Mass Spectrometer
    • Binary pump HPLC with microvacuum degaser
    • Temperature controlled, 100-vial autosampler
    • Dual column oven with a column switching valve
      o UV/Vis diode array detector
      o Orthogonal pneumatically assisted electrospray (ESI) and atmospheric pressure chemical ionization (APCI) sources
  • Agilent 1100 HPLC-MSD SL Ion Trap Mass Spectrometer
    • Binary pump HPLC with microvacuum degaser
    • Temperature controlled, 100-vial autosampler
    • Dual column oven with a column switching valve
    • UV/Vis diode array detector
    • Orthogonal pneumatically assisted electrospray (ESI) and atmospheric pressure chemical ionization (APCI) sources
  • Agilent 1100 HPLC-MSD VL Quadrupole Mass Spectrometer
    • Quaternary pump HPLC
    • 100-vial autosampler
    • UV/Vis variable wavelength detector
    • Atmospheric pressure chemical ionization (APCI) source

Spectrophotometry

  • Bruker Equinox 55/S FT–IR Spectrophotometer
    • Conventional and step scanning modes for time-resolved spectroscopy
    • Fast scan option
    • Dual sources for Near-IR and Mid-IR spectral ranges
    • DTGS, liquid-nitrogen-cooled MCT, and NIR Ge diode detectors
    • Various sampling accessories are available
  • Perkin–Elmer 599B IR Spectrophotometer
    • Double beam, optical null instrument with an f/5 filter grating monochrocator
    • 4000 to 200 cm–1 spectral range
    • Transmission cell holder
  • Hitachi F–3010 Fluorescence Spectrophotometer
    • Excitation or emission wavelength scans, time scan and quantitative measurement modes
    • Temperature-controlled cuvette holder with integrated stirring accessory
  • Perkin–Elmer 241 Polarimeter
    • Sodium and mercury lamp sources
    • Temperature-controlled cell having 1 mL volume and 1 dm pathlength

Miscellanea

  • Nikon Inverted Microscope